Tongue Imaging Analysis
![TIA-8.jpg](https://static.wixstatic.com/media/1f5b39_728e1372eefc4f9fb9bc2d2a22e55576~mv2.jpg/v1/fill/w_309,h_411,al_c,q_80,usm_0.66_1.00_0.01,enc_avif,quality_auto/TIA-8.jpg)
![TIA-9.jpg](https://static.wixstatic.com/media/1f5b39_1ce5009e50954f499542e06c885995ba~mv2.jpg/v1/fill/w_311,h_411,al_c,q_80,usm_0.66_1.00_0.01,enc_avif,quality_auto/TIA-9.jpg)
![TIA-4.jpg](https://static.wixstatic.com/media/1f5b39_373b76a3f0c544cf8239d2d38fe0647a~mv2.jpg/v1/fill/w_252,h_286,al_c,q_80,enc_avif,quality_auto/TIA-4.jpg)
The Tongue Imaging system looks to enhance the tongue diagnosis of TCM.
After taking a photo of the patient's tongue with the device to ensure consistency, the image is processed with a patented software and a tongue colour index, coating index and shape parameter is established
![TIA-2.jpg](https://static.wixstatic.com/media/1f5b39_d494e9d85f594ffd8457969183cdf449~mv2.jpg/v1/fill/w_262,h_124,al_c,q_80,enc_avif,quality_auto/TIA-2.jpg)
![TIA-3.jpg](https://static.wixstatic.com/media/1f5b39_8753ed1166b84226864592daeebaf714~mv2.jpg/v1/fill/w_465,h_167,al_c,q_80,enc_avif,quality_auto/TIA-3.jpg)
![TIA-5.jpg](https://static.wixstatic.com/media/1f5b39_0da594084a164e74b641b76da0399346~mv2.jpg/v1/fill/w_599,h_303,al_c,q_80,usm_0.66_1.00_0.01,enc_avif,quality_auto/TIA-5.jpg)
The patented colour imaging processing ensures high quality colour images.
​
After colour correction according to international standards, CIE-2000 applied.
​
CIE (Commision on Illuminations) defined as delta value is the inaccuracy to colour reference ideal with ideal being a value of 0.
Delta values of 3% cannot be identified by the human eye.
![TIA-6.1.jpg](https://static.wixstatic.com/media/1f5b39_9f3fe4b9800e479ca7c86859f68bece0~mv2.jpg/v1/fill/w_107,h_158,al_c,q_80,enc_avif,quality_auto/TIA-6_1.jpg)
![TIA-6.2.jpg](https://static.wixstatic.com/media/1f5b39_d7f8dad3e94a48ce8fc415b50aee8d4d~mv2.jpg/v1/fill/w_292,h_438,al_c,q_80,enc_avif,quality_auto/TIA-6_2.jpg)
Before Processing
![TIA-7.1.jpg](https://static.wixstatic.com/media/1f5b39_2e5e07151fd54d399fc1e2076e0a3e89~mv2.jpg/v1/fill/w_106,h_148,al_c,q_80,enc_avif,quality_auto/TIA-7_1.jpg)
![TIA-7.2.jpg](https://static.wixstatic.com/media/1f5b39_59b229e5b3b64626ab052295a748747a~mv2.jpg/v1/fill/w_294,h_439,al_c,q_80,enc_avif,quality_auto/TIA-7_2.jpg)
After Processing
Before processing the image of the tongue will register a delta value of above 12. In this example it is 13.98.
​
After processing however the picture is corrected to an average of delta value of 4. In this example 4.11
This product is currently available for purchase and testing